4-tert-Butyldimethylsilyl Atorvastatin LactoneVeeprho vp0c42c9dfa1NOOOSiFOHN
  • 100% accuracy of data
  • 24/7 scientific support
  • 0% tolerance in quality of product

Mutagenicity assessment (ICH M7)

ICH M7 class 4–5

Treated as a potentially non-mutagenic impurity (ICH M7 Class 4–5).

Computational (in silico) assessment
Computational (in silico) result: subject to change as the software and databases are updated. For a confirmed class, request the full report.
Request mutagenicity assessment

Stock Locations

  • New Jersey, USA
  • Czech Republic, EU

* Stock subject to availability.

Documentation

Includes: HPLC, MASS/LC-MS, 1H NMR, FT-IR, Potency, Structure Elucidation Report (SER), and additional analytical data depending on the product.

842162-99-6
4-tert-Butyldimethylsilyl Atorvastatin Lactone

● In Stock

Catalogue No.:VE0026751
CAS No.:842162-99-6
Mol. Formula:C39H47FN2O4Si
Mol. Weight:654.9 g/mol
Request a quote

For laboratory use only: analytical, development and regulatory purposes. Supplied in mg quantities. Not for human or veterinary use.

Additional information on CAS 842162-99-6

Parent drugAtorvastatin
Product typeImpurity standards
IUPAC name1-[2-[(2R,4R)-4-[tert-butyl(dimethyl)silyl]oxy-6-oxooxan-2-yl]ethyl]-5-(4-fluorophenyl)-N,4-diphenyl-2-propan-2-ylpyrrole-3-carboxamide
SMILESCC(C)C1=C(C(=C(N1CC[C@@H]2C[C@H](CC(=O)O2)O[Si](C)(C)C(C)(C)C)C3=CC=C(C=C3)F)C4=CC=CC=C4)C(=O)NC5=CC=CC=C5
InChIInChI=1S/C39H47FN2O4Si/c1-26(2)36-35(38(44)41-30-16-12-9-13-17-30)34(27-14-10-8-11-15-27)37(28-18-20-29(40)21-19-28)42(36)23-22-31-24-32(25-33(43)45-31)46-47(6,7)39(3,4)5/h8-21,26,31-32H,22-25H2,1-7H3,(H,41,44)/t31-,32-/m1/s1
InChIKeyJUHAOHJRZIHKIP-ROJLCIKYSA-N
CHNS Ratio (%) (calculated)C 71.53 · H 7.23 · N 4.28 · S 0.00
Description

4-tert-Butyldimethylsilyl Atorvastatin Lactone (CAS 842162-99-6) is a process-related silyl-protected atorvastatin lactone impurity formed during silylation, protection or incomplete deprotection steps. As a lipophilic, silicon-containing impurity it can persist through purification and impact assay accuracy, impurity profiling and stability testing. Reliable identification requires orthogonal techniques such as HPLC-UV, LC-MS/MS for mass confirmation and NMR for structural proof. Effective control relies on optimized deprotection, targeted in-process controls and validated analytical limits. Method development must address potential coelution, ion suppression and stability under forced-degradation conditions to meet regulatory impurity thresholds and ensure drug substance quality.⁠​​​​‌‌​​​‌​​​​‌​‌‌​​‌​​‌‌‌​‌‌‌‌‌‌​‌​​​​‌⁠

Request a Quote

"*" indicates required fields

We use your details only to answer this message. See our Privacy Policy.