Atorvastatin 5-Isopropyl Ether tert-Butyl EsterVeeprho vp34294a71aeONOOOHOFHN
  • 100% accuracy of data
  • 24/7 scientific support
  • 0% tolerance in quality of product

Mutagenicity assessment (ICH M7)

ICH M7 class 4–5

Treated as a potentially non-mutagenic impurity (ICH M7 Class 4–5).

Computational (in silico) assessment
Computational (in silico) result: subject to change as the software and databases are updated. For a confirmed class, request the full report.
Request mutagenicity assessment

Stock Locations

  • New Jersey, USA
  • Czech Republic, EU

* Stock subject to availability.

Documentation

Includes: HPLC, MASS/LC-MS, 1H NMR, FT-IR, Potency, Structure Elucidation Report (SER), and additional analytical data depending on the product.

Atorvastatin 5-Isopropyl Ether tert-Butyl Ester

● In Stock

Catalogue No.:VE0026708
CAS No.:N/A
Mol. Formula:C40H49FN2O5
Mol. Weight:656.8 g/mol
Request a quote

For laboratory use only: analytical, development and regulatory purposes. Supplied in mg quantities. Not for human or veterinary use.

Additional information on Atorvastatin 5-Isopropyl Ether tert-Butyl Ester

Parent drugAtorvastatin
Product typeImpurity standards
IUPAC nameTert-butyl (3R,5R)-7-[2-(4-fluorophenyl)-3-phenyl-4-(phenylcarbamoyl)-5-propan-2-ylpyrrol-1-yl]-3-hydroxy-5-propan-2-yloxyheptanoate
SMILESO=C(C1=C(C(C)C)N(CC[C@H](C[C@H](CC(OC(C)(C)C)=O)O)OC(C)C)C(C2=CC=C(F)C=C2)=C1C3=CC=CC=C3)NC4=CC=CC=C4
InChIInChI=1S/C40H49FN2O5/c1-26(2)37-36(39(46)42-31-16-12-9-13-17-31)35(28-14-10-8-11-15-28)38(29-18-20-30(41)21-19-29)43(37)23-22-33(47-27(3)4)24-32(44)25-34(45)48-40(5,6)7/h8-21,26-27,32-33,44H,22-25H2,1-7H3,(H,42,46)/t32-,33-/m1/s1
InChIKeyQIIBYWHIVDQMRK-CZNDPXEESA-N
CHNS Ratio (%) (calculated)C 73.14 · H 7.52 · N 4.26 · S 0.00
Description

Atorvastatin 5-Isopropyl Ether tert-Butyl Ester impurity is a process-related synthetic byproduct encountered during atorvastatin esterification and alkylation steps. Characterized by LC-MS and confirmed by 1H and 13C NMR, this lipophilic ester impurity can form from incomplete deprotection or over-alkylation of the isopropyl ether intermediate and may coelute with target analytes, affecting assay accuracy and stability profiles. Routine impurity profiling by validated reverse-phase HPLC with MS detection is recommended, alongside control measures such as optimized stoichiometry, selective protection-deprotection strategies and purification by column chromatography or preparative HPLC, with qualification aligned to ICH impurity thresholds and risk assessment.⁠​​‌‌​‌​​​​‌​‌​​‌​‌​​‌​‌​​‌‌‌​​​‌‌​‌​‌‌‌​⁠

Request a Quote

"*" indicates required fields

We use your details only to answer this message. See our Privacy Policy.