Atorvastatin Impurity 147Veeprho vp3a9e431c1cOOOFOHN
  • 100% accuracy of data
  • 24/7 scientific support
  • 0% tolerance in quality of product

Mutagenicity assessment (ICH M7)

ICH M7 class 4–5

Treated as a potentially non-mutagenic impurity (ICH M7 Class 4–5).

Computational (in silico) assessment
Computational (in silico) result: subject to change as the software and databases are updated. For a confirmed class, request the full report.
Request mutagenicity assessment

Stock Locations

  • New Jersey, USA
  • Czech Republic, EU

* Stock subject to availability.

Documentation

Includes: HPLC, MASS/LC-MS, 1H NMR, FT-IR, Potency, Structure Elucidation Report (SER), and additional analytical data depending on the product.

Atorvastatin Impurity 147

● In Stock

Catalogue No.:VE0026722
CAS No.:N/A
Mol. Formula:C34H30FNO4
Mol. Weight:535.6 g/mol
Request a quote

For laboratory use only: analytical, development and regulatory purposes. Supplied in mg quantities. Not for human or veterinary use.

Additional information on Atorvastatin Impurity 147

Parent drugAtorvastatin
Product typeImpurity standards
IUPAC name2-[2-(4-fluorophenyl)-2-oxo-1-[4-(2-phenylacetyl)phenyl]ethyl]-4-methyl-3-oxo-N-phenylpentanamide
SMILESCC(C)C(=O)C(C(C1=CC=C(C=C1)C(=O)CC2=CC=CC=C2)C(=O)C3=CC=C(C=C3)F)C(=O)NC4=CC=CC=C4
InChIInChI=1S/C34H30FNO4/c1-22(2)32(38)31(34(40)36-28-11-7-4-8-12-28)30(33(39)26-17-19-27(35)20-18-26)25-15-13-24(14-16-25)29(37)21-23-9-5-3-6-10-23/h3-20,22,30-31H,21H2,1-2H3,(H,36,40)
InChIKeyQOMSTWOVYPGODD-UHFFFAOYSA-N
CHNS Ratio (%) (calculated)C 76.24 · H 5.65 · N 2.62 · S 0.00
Description

Atorvastatin Impurity 147 is a discrete process- or degradation-related impurity observed during atorvastatin synthesis and stability studies, characterized by a reproducible chromatographic peak and a distinct LC-MS fragmentation profile, which necessitates dedicated method development for accurate quantitation. Its generation is typically linked to late-stage oxidative or transesterification pathways, requiring targeted process controls and impurity rejection steps. Structural confirmation relies on high-resolution mass spectrometry and NMR when isolation is practical. Control strategy aligns with ICH guidance for reporting, identification and qualification, using validated stability-indicating HPLC and LC-MS assays to support reliable detection, assessment and batch disposition.⁠​​‌‌‌​‌​‌​​‌‌‌‌​​‌​​​​‌‌​​​‌‌‌​​​​​‌‌‌​​⁠

Request a Quote

"*" indicates required fields

We use your details only to answer this message. See our Privacy Policy.