Atorvastatin Impurity 99Veeprho vp88454dae98ONOFOHNHO
  • 100% accuracy of data
  • 24/7 scientific support
  • 0% tolerance in quality of product

Mutagenicity assessment (ICH M7)

ICH M7 class 1–3

Potentially mutagenic impurity (ICH M7 Class 1–3).

Computational (in silico) assessment
Computational (in silico) result: subject to change as the software and databases are updated. For a confirmed class, request the full report.
Request mutagenicity assessment

Stock Locations

  • New Jersey, USA
  • Czech Republic, EU

* Stock subject to availability.

Documentation

Includes: HPLC, MASS/LC-MS, 1H NMR, FT-IR, Potency, Structure Elucidation Report (SER), and additional analytical data depending on the product.

Atorvastatin Impurity 99

● In Stock

Catalogue No.:VE0026714
CAS No.:N/A
Mol. Formula:C26H23FN2O4
Mol. Weight:446.5 g/mol
Request a quote

For laboratory use only: analytical, development and regulatory purposes. Supplied in mg quantities. Not for human or veterinary use.

Additional information on Atorvastatin Impurity 99

Parent drugAtorvastatin
Product typeImpurity standards
IUPAC name2-(4-fluorophenyl)-5-hydroxy-N,1-diphenyl-5-propan-2-yl-3,7-dioxa-4-azatricyclo[4.1.0.02,4]heptane-6-carboxamide
SMILESCC(C)C1(C2(C(O2)(C3(N1O3)C4=CC=C(C=C4)F)C5=CC=CC=C5)C(=O)NC6=CC=CC=C6)O
InChIInChI=1S/C26H23FN2O4/c1-17(2)25(31)24(22(30)28-21-11-7-4-8-12-21)23(32-24,18-9-5-3-6-10-18)26(29(25)33-26)19-13-15-20(27)16-14-19/h3-17,31H,1-2H3,(H,28,30)
InChIKeyZMMUGFZYQOKNFN-UHFFFAOYSA-N
CHNS Ratio (%) (calculated)C 69.94 · H 5.19 · N 6.27 · S 0.00
Description

Atorvastatin Impurity 99 is a trace related compound identified in atorvastatin batches that impacts purity and stability. It is characterized by chromatographic retention behavior and a distinct mass spectral fingerprint, enabling differentiation from the parent drug and known degradants. Routine control requires validated HPLC and LC-MS methods with appropriate resolution, limits of quantitation, and forced-degradation studies to elucidate formation pathways. Accurate quantification supports specification setting and impurity profiling for regulatory submissions. Understanding its polarity, UV absorbance and potential synthetic or oxidative origins informs remediation strategies during process optimization and stability monitoring to maintain product quality.⁠‌​​​‌​​​​‌​​​‌​‌​‌​​‌‌​‌‌​‌​‌‌‌​‌​​‌‌​​​⁠

Request a Quote

"*" indicates required fields

We use your details only to answer this message. See our Privacy Policy.