Atorvastatin Lactam Methyl EsterVeeprho vp8d60ee3b30NOOOOHOHFONH
  • 100% accuracy of data
  • 24/7 scientific support
  • 0% tolerance in quality of product

Mutagenicity assessment (ICH M7)

ICH M7 class 1–3

Potentially mutagenic impurity (ICH M7 Class 1–3).

Computational (in silico) assessment
Computational (in silico) result: subject to change as the software and databases are updated. For a confirmed class, request the full report.
Request mutagenicity assessment

Stock Locations

  • New Jersey, USA
  • Czech Republic, EU

* Stock subject to availability.

Documentation

Includes: HPLC, MASS/LC-MS, 1H NMR, FT-IR, Potency, Structure Elucidation Report (SER), and additional analytical data depending on the product.

1795790-02-1
Atorvastatin Lactam Methyl Ester

● In Stock

Catalogue No.:VE0026745
CAS No.:1795790-02-1
Mol. Formula:C34H37FN2O6
Mol. Weight:588.7 g/mol
Request a quote

For laboratory use only: analytical, development and regulatory purposes. Supplied in mg quantities. Not for human or veterinary use.

Additional information on CAS 1795790-02-1

Parent drugAtorvastatin
Product typeImpurity standards
IUPAC namemethyl (3R,5R)-7-[5-(4-fluorophenyl)-2-oxo-4-phenyl-3-(phenylcarbamoyl)-3-propan-2-ylpyrrol-1-yl]-3,5-dihydroxyheptanoate
SMILESCC(C)C1(C(=C(N(C1=O)CC[C@H](C[C@H](CC(=O)OC)O)O)C2=CC=C(C=C2)F)C3=CC=CC=C3)C(=O)NC4=CC=CC=C4
InChIInChI=1S/C34H37FN2O6/c1-22(2)34(32(41)36-26-12-8-5-9-13-26)30(23-10-6-4-7-11-23)31(24-14-16-25(35)17-15-24)37(33(34)42)19-18-27(38)20-28(39)21-29(40)43-3/h4-17,22,27-28,38-39H,18-21H2,1-3H3,(H,36,41)/t27-,28-,34?/m1/s1
InChIKeyYNGOMPIJVFEMSM-VNPSQQOISA-N
CHNS Ratio (%) (calculated)C 69.37 · H 6.34 · N 4.76 · S 0.00
Description

Atorvastatin Lactam Methyl Ester (CAS 1795790-02-1) is a process-related impurity encountered in atorvastatin manufacturing, arising from methylation or incomplete lactam formation during esterification and workup. Structurally defined by a methyl ester substitution on the lactam ring, this impurity requires sensitive detection and quantitation by HPLC-UV with orthogonal confirmation using LC-MS and NMR for accurate impurity profiling. Monitoring and control in line with ICH Q3A/Q3B involve optimized reaction parameters, targeted purification steps, and validated stability-indicating assays to limit carryover, assess degradation pathways, and ensure product quality, safety, and consistent shelf life.⁠‌​​​‌‌​‌​‌‌​​​​​‌‌‌​‌‌‌​​​‌‌‌​‌‌​​‌‌​​​​⁠

Request a Quote

"*" indicates required fields

We use your details only to answer this message. See our Privacy Policy.