3,5-Di(tert-butyldimethylsilyl) RosuvastatinVeeprho vp3fe19f34beFOSiOHOOSiNNSOON
  • 100% accuracy of data
  • 24/7 scientific support
  • 0% tolerance in quality of product

Mutagenicity assessment (ICH M7)

ICH M7 class 4–5

Treated as a potentially non-mutagenic impurity (ICH M7 Class 4–5).

Computational (in silico) assessment
Computational (in silico) result: subject to change as the software and databases are updated. For a confirmed class, request the full report.
Request mutagenicity assessment

Stock Locations

  • New Jersey, USA
  • Czech Republic, EU

* Stock subject to availability.

Documentation

Includes: HPLC, MASS/LC-MS, 1H NMR, FT-IR, Potency, Structure Elucidation Report (SER), and additional analytical data depending on the product.

3,5-Di(tert-butyldimethylsilyl) Rosuvastatin

● In Stock

Catalogue No.:VE0026615
CAS No.:N/A
Mol. Formula:C34H56FN3O6SSi2
Mol. Weight:710.1 g/mol
Request a quote

For laboratory use only: analytical, development and regulatory purposes. Supplied in mg quantities. Not for human or veterinary use.

Additional information on 3,5-Di(tert-butyldimethylsilyl) Rosuvastatin

Parent drugRosuvastatin
Product typeImpurity standards
IUPAC name(E,3R,5S)-3,5-bis[[tert-butyl(dimethyl)silyl]oxy]-7-[4-(4-fluorophenyl)-2-[methyl(methylsulfonyl)amino]-6-propan-2-ylpyrimidin-5-yl]hept-6-enoic acid
SMILESFC1=CC=C(C2=C(/C=C/[C@@H](O[Si](C)(C(C)(C)C)C)C[C@H](CC(O)=O)O[Si](C)(C)C(C)(C)C)C(C(C)C)=NC(N(S(=O)(C)=O)C)=N2)C=C1
InChIInChI=1S/C34H56FN3O6SSi2/c1-23(2)30-28(31(24-15-17-25(35)18-16-24)37-32(36-30)38(9)45(10,41)42)20-19-26(43-46(11,12)33(3,4)5)21-27(22-29(39)40)44-47(13,14)34(6,7)8/h15-20,23,26-27H,21-22H2,1-14H3,(H,39,40)/b20-19+/t26-,27-/m1/s1
InChIKeyXAOQVMRJPZGRCX-ZVFYLXQQSA-N
CHNS Ratio (%) (calculated)C 57.51 · H 7.95 · N 5.92 · S 4.52
Description

3,5-Di(tert-butyldimethylsilyl) Rosuvastatin impurity arises as a silyl-protected byproduct during rosuvastatin synthesis and presents specific analytical and control challenges. It is characterized by increased lipophilicity, diagnostic silyl fragment ions in LC-MS, and distinctive 1H and 13C NMR resonances attributable to tert-butyldimethylsilyl moieties. Routine impurity profiling uses reverse phase HPLC with UV and MS detection together with orthogonal NMR confirmation. Formation is often driven by residual silylation reagents or incomplete deprotection, with potential impact on assay accuracy and stability. Robust monitoring, validated analytical methods, targeted purification and defined specification limits are required to mitigate risk and ensure batch consistency.⁠​​‌‌‌‌‌‌‌‌‌​​​​‌‌​​‌‌‌‌‌​​‌‌​‌​​‌​‌‌‌‌‌​⁠

Request a Quote

"*" indicates required fields

We use your details only to answer this message. See our Privacy Policy.