5-Pyrimidinecarboxylic acid, 4-(4-fluorophenyl)-6-(1-methylethyl)-2-[methyl(methylsulfonyl)amino]-Veeprho vp7c2c2a768aNNFOHONSOO
  • 100% accuracy of data
  • 24/7 scientific support
  • 0% tolerance in quality of product

Mutagenicity assessment (ICH M7)

ICH M7 class 4–5

Treated as a potentially non-mutagenic impurity (ICH M7 Class 4–5).

Computational (in silico) assessment
Computational (in silico) result: subject to change as the software and databases are updated. For a confirmed class, request the full report.
Request mutagenicity assessment

Stock Locations

  • New Jersey, USA
  • Czech Republic, EU

* Stock subject to availability.

Documentation

Includes: HPLC, MASS/LC-MS, 1H NMR, FT-IR, Potency, Structure Elucidation Report (SER), and additional analytical data depending on the product.

1263475-93-9
5-Pyrimidinecarboxylic acid, 4-(4-fluorophenyl)-6-(1-methylethyl)-2-[methyl(methylsulfonyl)amino]-

● In Stock

Catalogue No.:VE0026681
CAS No.:1263475-93-9
Mol. Formula:C16H18FN3O4S
Mol. Weight:367.40 g/mol
Request a quote

For laboratory use only: analytical, development and regulatory purposes. Supplied in mg quantities. Not for human or veterinary use.

Additional information on CAS 1263475-93-9

Parent drugRosuvastatin
Product typeImpurity standards
IUPAC name4-(4-fluorophenyl)-2-[methyl(methylsulfonyl)amino]-6-propan-2-ylpyrimidine-5-carboxylic acid
SMILESCN(C1=NC(C2=CC=C(F)C=C2)=C(C(O)=O)C(C(C)C)=N1)S(C)(=O)=O
InChIInChI=1S/C16H18FN3O4S/c1-9(2)13-12(15(21)22)14(10-5-7-11(17)8-6-10)19-16(18-13)20(3)25(4,23)24/h5-9H,1-4H3,(H,21,22)
InChIKeyCHMLXRMRDRNBMV-UHFFFAOYSA-N
CHNS Ratio (%) (calculated)C 52.31 · H 4.94 · N 11.44 · S 8.73
Description

5-Pyrimidinecarboxylic acid, 4-(4-fluorophenyl)-6-(1-methylethyl)-2-[methyl(methylsulfonyl)amino], CAS 1263475-93-9, is a synthetic process-related impurity encountered in pyrimidine-based manufacture. With a fluorophenyl moiety and a methylsulfonylated amino substituent the impurity exhibits moderate polarity and characteristic UV absorbance that facilitate HPLC-UV detection. Analytical characterization typically uses LC-MS, high-resolution MS and 1H/13C NMR to confirm exact mass and substitution pattern while retention behavior and diagnostic fragments support trace-level monitoring. Defining the impurity profile requires validated HPLC methods with established LOD and LOQ, targeted purification or reaction optimization, and stability and forced-degradation data for specification setting and regulatory documentation.⁠​‌‌‌‌‌​​​​‌​‌‌​​​​‌​‌​‌​​‌‌‌​‌‌​‌​​​‌​‌​⁠

Request a Quote

"*" indicates required fields

We use your details only to answer this message. See our Privacy Policy.