N-Nitroso Atorvastatin EP Impurity MVeeprho vpef5be7f312ONOHOHOOFNNO
  • 100% accuracy of data
  • 24/7 scientific support
  • 0% tolerance in quality of product

Mutagenicity assessment (ICH M7)

ICH M7 class 1–3

Potentially mutagenic impurity (ICH M7 Class 1–3).

N-nitroso compound: ICH M7 cohort of concern.
Request mutagenicity assessment

Stock Locations

  • New Jersey, USA
  • Czech Republic, EU

* Stock subject to availability.

Documentation

Includes: HPLC, MASS/LC-MS, 1H NMR, FT-IR, Potency, Structure Elucidation Report (SER), and additional analytical data depending on the product.

N-Nitroso Atorvastatin EP Impurity M

● Under Development

Catalogue No.:VE0027947
CAS No.:N/A
Mol. Formula:C35H38FN3O6
Mol. Weight:615.69 g/mol
Request a quote

For laboratory use only: analytical, development and regulatory purposes. Supplied in mg quantities. Not for human or veterinary use.

Request a quote for a set

Additional information on N-Nitroso Atorvastatin EP Impurity M

Parent drugAtorvastatin
Product typeImpurity standards, Nitroso impurities
IUPAC name(3R,5R)-ethyl 7-(2-(4-fluorophenyl)-5-isopropyl-4-(nitroso(phenyl)carbamoyl)-3-phenyl-1H-pyrrol-1-yl)-3,5-dihydroxyheptanoate
SMILESO=C(C1=C(C(C)C)N(CC[C@@]([H])(O)C[C@](O)([H])CC(OCC)=O)C(C2=CC=C(F)C=C2)=C1C3=CC=CC=C3)N(N=O)C4=CC=CC=C4
InChIInChI=1S/C35H38FN3O6/c1-4-45-30(42)22-29(41)21-28(40)19-20-38-33(23(2)3)32(35(43)39(37-44)27-13-9-6-10-14-27)31(24-11-7-5-8-12-24)34(38)25-15-17-26(36)18-16-25/h5-18,23,28-29,40-41H,4,19-22H2,1-3H3/t28-,29-/m1/s1
InChIKeyJSSMCEHZNBTLPA-FQLXRVMXSA-N
CHNS Ratio (%) (calculated)C 68.28 · H 6.22 · N 6.82 · S 0.00
Description

N-Nitroso Atorvastatin EP Impurity M is a nitrosamine-class genotoxic impurity identified in atorvastatin API batches and stability samples; thorough characterization typically combines high-resolution mass spectrometry and NMR to confirm nitroso substitution and elemental composition. Formation is commonly linked to nitrosation of amine precursors under acidic or nitrosating conditions, so control of residual nitrite, pH, and reaction quench is essential. Robust quantitative methods such as validated LC-MS/MS or GC-MS with optimized sample preparation are required for sensitive detection, ICH M7 risk-based assessment, limit setting, root-cause investigation, and implementation of effective mitigation strategies during process development and quality control.⁠‌‌‌​‌‌‌‌​‌​‌‌​‌‌‌‌‌​​‌‌‌‌‌‌‌​​‌‌​​​‌​​‌​⁠

Request a Quote

"*" indicates required fields

We use your details only to answer this message. See our Privacy Policy.