N-Nitroso Palbociclib Intermediate Stage IIVeeprho vp713748d1b2ONNNNONNOONNO
  • 100% accuracy of data
  • 24/7 scientific support
  • 0% tolerance in quality of product

Mutagenicity assessment (ICH M7)

ICH M7 class 1–3

Potentially mutagenic impurity (ICH M7 Class 1–3).

N-nitroso compound: ICH M7 cohort of concern.
Request mutagenicity assessment

Stock Locations

  • New Jersey, USA
  • Czech Republic, EU

* Stock subject to availability.

Documentation

Includes: HPLC, MASS/LC-MS, 1H NMR, FT-IR, Potency, Structure Elucidation Report (SER), and additional analytical data depending on the product.

N-Nitroso Palbociclib Intermediate Stage II

● Report Available Immediately

Catalogue No.:VE0027807
CAS No.:N/A
Mol. Formula:C33H44N8O5
Mol. Weight:632.75 g/mol
Request a quote

For laboratory use only: analytical, development and regulatory purposes. Supplied in mg quantities. Not for human or veterinary use.

Request a quote for a set

Additional information on N-Nitroso Palbociclib Intermediate Stage II

Parent drugPalbociclib
Product typeImpurity standards, Nitroso impurities
IUPAC nametert-butyl 4-(6-((6-(1-butoxyvinyl)-8-cyclopentyl-5-methyl-7-oxo-7,8-dihydropyrido[2,3-d]pyrimidin-2-yl)(nitroso)amino)pyridin-3-yl)piperazine-1-carboxylate
SMILESO=C1N(C2CCCC2)C3=NC(N(N=O)C4=CC=C(N5CCN(C(OC(C)(C)C)=O)CC5)C=N4)=NC=C3C(C)=C1C(OCCCC)=C
InChIInChI=1S/C33H44N8O5/c1-7-8-19-45-23(3)28-22(2)26-21-35-31(36-29(26)40(30(28)42)24-11-9-10-12-24)41(37-44)27-14-13-25(20-34-27)38-15-17-39(18-16-38)32(43)46-33(4,5)6/h13-14,20-21,24H,3,7-12,15-19H2,1-2,4-6H3
InChIKeyYRZGPOJOZOGYKP-UHFFFAOYSA-N
CHNS Ratio (%) (calculated)C 62.64 · H 7.01 · N 17.71 · S 0.00
Description

N-Nitroso Palbociclib Intermediate Stage II impurity is an N-nitrosamine byproduct arising from nitrosation of secondary amines during Stage II synthesis of palbociclib intermediates. This impurity presents a potential genotoxic concern typical of nitrosamines and requires targeted control strategies and sensitive monitoring. Analytical characterization employs LC-MS/MS, high resolution mass spectrometry, and selective sample preparation to achieve low limits of detection and robust quantitation. Risk mitigation focuses on preventing formation through exclusion of nitrosating reagents, pH and solvent optimization, targeted purification and validated in-process controls in line with ICH M7 principles, with stability and specification studies guiding batch release.⁠​‌‌‌​​​‌​​‌‌​‌‌‌​‌​​‌​​​‌‌​‌​​​‌‌​‌‌​​‌​⁠

Request a Quote

"*" indicates required fields

We use your details only to answer this message. See our Privacy Policy.