- 100% accuracy of data
- 24/7 scientific support
- 0% tolerance in quality of product
Mutagenicity assessment (ICH M7)
Treated as a potentially non-mutagenic impurity (ICH M7 Class 4–5).
Computational (in silico) assessmentStock Locations
- New Jersey, USA
- Czech Republic, EU
* Stock subject to availability.
Documentation
Includes: HPLC, MASS/LC-MS, 1H NMR, FT-IR, Potency, Structure Elucidation Report (SER), and additional analytical data depending on the product.
Rosuvastatin Impurity 164
● In Stock
| Catalogue No.: | VE0026618 |
|---|---|
| CAS No.: | N/A |
| Mol. Formula: | C42H54F2N6O9S2 |
| Mol. Weight: | 889.04 g/mol |
For laboratory use only: analytical, development and regulatory purposes. Supplied in mg quantities. Not for human or veterinary use.
Additional information on Rosuvastatin Impurity 164
| Parent drug | Rosuvastatin |
|---|---|
| Product type | Impurity standards |
| IUPAC name | tert-butyl (E,3R,5S)-7-[4-(4-fluorophenyl)-2-[[2-[4-(4-fluorophenyl)-2-[methyl(methylsulfonyl)amino]-6-propan-2-ylpyrimidin-5-yl]-2-hydroxyethyl]sulfonyl-methylamino]-6-propan-2-ylpyrimidin-5-yl]-3,5-dihydroxyhept-6-enoate |
| SMILES | FC1=CC=C(C=C1)C2=C(/C([H])=C([H])/[C@@H](O)C[C@@H](O)CC(OC(C)(C)C)=O)C(C(C)C)=NC(N(S(=O)(CC(O)C3=C(C4=CC=C(F)C=C4)N=C(N(C)S(C)(=O)=O)N=C3C(C)C)=O)C)=N2 |
| InChI | InChI=1S/C42H54F2N6O9S2/c1-24(2)36-32(20-19-30(51)21-31(52)22-34(54)59-42(5,6)7)38(26-11-15-28(43)16-12-26)47-41(45-36)50(9)61(57,58)23-33(53)35-37(25(3)4)46-40(49(8)60(10,55)56)48-39(35)27-13-17-29(44)18-14-27/h11-20,24-25,30-31,33,51-53H,21-23H2,1-10H3/b20-19+/t30-,31-,33?/m1/s1 |
| InChIKey | DHJHFCIOODIQSD-YLSCRCBRSA-N |
| CHNS Ratio (%) (calculated) | C 56.74 · H 6.12 · N 9.45 · S 7.21 |
| Description | Rosuvastatin Impurity 164 is a structure-related degradant observed in stability studies of rosuvastatin formulations. Characterized by LC-MS and 1H NMR, it displays a distinct retention time and a molecular ion consistent with a demethylation or ring-opened product, requiring targeted analytical methods for reliable quantitation. Laboratories apply gradient HPLC with UV detection and orthogonal LC-MS confirmation to establish limits, identification and qualification per ICH Q3A/B guidelines. Its presence can affect assay accuracy and stability profiling, therefore forced degradation, impurity profiling and validated methods with LOQ and LOD assessments are essential for robust impurity control and pharmaceutical quality assurance. |
Request a Quote
"*" indicates required fields

