Rosuvastatin Impurity 168Veeprho vp26321065cdNSOOHONFHON
  • 100% accuracy of data
  • 24/7 scientific support
  • 0% tolerance in quality of product

Mutagenicity assessment (ICH M7)

ICH M7 class 4–5

Treated as a potentially non-mutagenic impurity (ICH M7 Class 4–5).

Computational (in silico) assessment
Computational (in silico) result: subject to change as the software and databases are updated. For a confirmed class, request the full report.
Request mutagenicity assessment

Stock Locations

  • New Jersey, USA
  • Czech Republic, EU

* Stock subject to availability.

Documentation

Includes: HPLC, MASS/LC-MS, 1H NMR, FT-IR, Potency, Structure Elucidation Report (SER), and additional analytical data depending on the product.

2101546-08-9
Rosuvastatin Impurity 168

● In Stock

Catalogue No.:VE0026663
CAS No.:2101546-08-9
Mol. Formula:C19H26FN3O4S
Mol. Weight:411.5 g/mol
Request a quote

For laboratory use only: analytical, development and regulatory purposes. Supplied in mg quantities. Not for human or veterinary use.

Additional information on CAS 2101546-08-9

Parent drugRosuvastatin
Product typeImpurity standards
IUPAC nameN-[4-(4-fluorophenyl)-5-(hydroxymethyl)-6-propan-2-ylpyrimidin-2-yl]-2-hydroxy-N,2-dimethylpropane-1-sulfonamide
SMILESCN(S(=O)(CC(C)(O)C)=O)C1=NC(C2=CC=C(F)C=C2)=C(CO)C(C(C)C)=N1
InChIInChI=1S/C19H26FN3O4S/c1-12(2)16-15(10-24)17(13-6-8-14(20)9-7-13)22-18(21-16)23(5)28(26,27)11-19(3,4)25/h6-9,12,24-25H,10-11H2,1-5H3
InChIKeyPJGZBNBFZFJZSE-UHFFFAOYSA-N
CHNS Ratio (%) (calculated)C 55.46 · H 6.37 · N 10.21 · S 7.79
Description

Rosuvastatin Impurity 168 is a process-related impurity observed during rosuvastatin active pharmaceutical ingredient synthesis and stability studies. Characterization typically relies on HPLC coupled with high resolution LC-MS and NMR to establish structure, elucidate formation pathways and assess mass balance. This impurity may arise from incomplete reaction, hydrolytic or oxidative degradation and requires identification and qualification in line with ICH Q3A Q3B thresholds. Control strategies include optimized reaction conditions, targeted purification and in-process monitoring to maintain specification limits. Robust analytical methods and stability stress testing are essential to quantify Impurity 168, define acceptance criteria and mitigate its impact on API quality and batch reproducibility.⁠​​‌​​‌‌​​​‌‌​​‌​​​​‌​​​​​‌‌​​‌​‌‌‌​​‌‌​‌⁠

Request a Quote

"*" indicates required fields

We use your details only to answer this message. See our Privacy Policy.