Rosuvastatin Impurity 170Veeprho vp4384528c89OHOOSNSO
  • 100% accuracy of data
  • 24/7 scientific support
  • 0% tolerance in quality of product

Mutagenicity assessment (ICH M7)

ICH M7 class 4–5

Treated as a potentially non-mutagenic impurity (ICH M7 Class 4–5).

Computational (in silico) assessment
Computational (in silico) result: subject to change as the software and databases are updated. For a confirmed class, request the full report.
Request mutagenicity assessment

Stock Locations

  • New Jersey, USA
  • Czech Republic, EU

* Stock subject to availability.

Documentation

Includes: HPLC, MASS/LC-MS, 1H NMR, FT-IR, Potency, Structure Elucidation Report (SER), and additional analytical data depending on the product.

Rosuvastatin Impurity 170

● In Stock

Catalogue No.:VE0026594
CAS No.:N/A
Mol. Formula:C16H19NO4S2
Mol. Weight:353.46 g/mol
Request a quote

For laboratory use only: analytical, development and regulatory purposes. Supplied in mg quantities. Not for human or veterinary use.

Additional information on Rosuvastatin Impurity 170

Parent drugRosuvastatin
Product typeImpurity standards
IUPAC name2-[(4R,6S)-6-(1,3-benzothiazol-2-ylsulfanylmethyl)-2,2-dimethyl-1,3-dioxan-4-yl]acetic acid
SMILESOC(C[C@@H](C1)OC(C)(C)O[C@@H]1CSC2=NC3=CC=CC=C3S2)=O
InChIInChI=1S/C16H19NO4S2/c1-16(2)20-10(8-14(18)19)7-11(21-16)9-22-15-17-12-5-3-4-6-13(12)23-15/h3-6,10-11H,7-9H2,1-2H3,(H,18,19)/t10-,11+/m1/s1
InChIKeyOQKSFXFLKHMNTG-MNOVXSKESA-N
CHNS Ratio (%) (calculated)C 54.37 · H 5.42 · N 3.96 · S 18.14
Description

Rosuvastatin Impurity 170 is a low-level synthetic or degradation byproduct detected in rosuvastatin drug substance batches that requires targeted analytical control. Characterized through LC-HRMS, HPLC-UV and NMR spectroscopy, this impurity exhibits increased polarity relative to the parent and a distinct retention time enabling reliable separation and quantification. Identification and structural elucidation support risk assessment for safety and stability, informing purification strategies and manufacturing parameter adjustments to minimize formation. Quantitative limits are established per ICH impurity guidelines and monitored via validated LC-MS/MS methods. Robust control includes precursor quality, optimized reaction conditions, and stability testing to ensure consistent impurity profiles within specification.⁠​‌​​​​‌‌‌​​​​‌​​​‌​‌​​‌​‌​​​‌‌​​‌​​​‌​​‌⁠