N-Nitroso Darolutamide Amide ImpurityVeeprho vp1959e77995ClNNNHNNNNOOO
  • 100% accuracy of data
  • 24/7 scientific support
  • 0% tolerance in quality of product

Mutagenicity assessment (ICH M7)

ICH M7 class 1–3

Potentially mutagenic impurity (ICH M7 Class 1–3).

N-nitroso compound: ICH M7 cohort of concern.
Request mutagenicity assessment

Stock Locations

  • New Jersey, USA
  • Czech Republic, EU

* Stock subject to availability.

Documentation

Includes: HPLC, MASS/LC-MS, 1H NMR, FT-IR, Potency, Structure Elucidation Report (SER), and additional analytical data depending on the product.

N-Nitroso Darolutamide Amide Impurity

● Report Available Immediately

Catalogue No.:VE0027831
CAS No.:N/A
Mol. Formula:C19H16ClN7O3
Mol. Weight:425.83 g/mol
Request a quote

For laboratory use only: analytical, development and regulatory purposes. Supplied in mg quantities. Not for human or veterinary use.

Request a quote for a set

Additional information on N-Nitroso Darolutamide Amide Impurity

Parent drugDarolutamide
Product typeImpurity standards, Nitroso impurities
IUPAC name(S)-5-acetyl-N-(1-(3-(3-chloro-4-cyanophenyl)-1H-pyrazol-1-yl)propan-2-yl)-1-nitroso-1H-pyrazole-3-carboxamide
SMILESClC1=C(C#N)C=CC(C2=NN(C=C2)C[C@H](C)NC(C3=NN(N=O)C(C(C)=O)=C3)=O)=C1
InChIInChI=1S/C19H16ClN7O3/c1-11(22-19(29)17-8-18(12(2)28)27(24-17)25-30)10-26-6-5-16(23-26)13-3-4-14(9-21)15(20)7-13/h3-8,11H,10H2,1-2H3,(H,22,29)/t11-/m0/s1
InChIKeyATQFHXXSWJPYET-NSHDSACASA-N
CHNS Ratio (%) (calculated)C 53.59 · H 3.79 · N 23.03 · S 0.00
Description

N-Nitroso Darolutamide Amide Impurity is a process-related nitrosamine impurity requiring targeted analytical characterization and control. Its formation can occur during amide coupling or nitrosating conditions and it demands trace-level detection by LC-MS/MS or GC-MS after appropriate sample preparation. Identification, quantification and structural confirmation support impurity profiling, stability studies and specification setting. Given the genotoxic potential of nitrosamines, risk assessment, root cause analysis, controlled synthesis conditions, quench strategies and validated monitoring are recommended to meet ICH M7 guidance and regulatory expectations. Robust methods provide limits of quantitation, recovery, and system suitability to ensure product safety and compliance.⁠​​​‌‌​​‌​‌​‌‌​​‌‌‌‌​​‌‌‌​‌‌‌‌​​‌‌​​‌​‌​‌⁠

Request a Quote

"*" indicates required fields

We use your details only to answer this message. See our Privacy Policy.