- 100% accuracy of data
- 24/7 scientific support
- 0% tolerance in quality of product
Mutagenicity assessment (ICH M7)
Potentially mutagenic impurity (ICH M7 Class 1–3).
N-nitroso compound: ICH M7 cohort of concern.Stock Locations
- New Jersey, USA
- Czech Republic, EU
* Stock subject to availability.
Documentation
Includes: HPLC, MASS/LC-MS, 1H NMR, FT-IR, Potency, Structure Elucidation Report (SER), and additional analytical data depending on the product.
N-Nitroso Losartan EP Impurity E
● Under Development
| Catalogue No.: | VE0027960 |
|---|---|
| CAS No.: | N/A |
| Mol. Formula: | C14H11N5O |
| Mol. Weight: | 265.27 g/mol |
For laboratory use only: analytical, development and regulatory purposes. Supplied in mg quantities. Not for human or veterinary use.
Request a quote for a set
- Request quote for this set
All nitrosamine impurities of Losartan
12 productsSee the 12 products
- N-Nitroso Losartan EP Impurity B VE0027958
- N-Nitroso Losartan EP Impurity C VE0027959
- N-Nitroso Losartan EP Impurity E VE0027960
- N-Nitroso Losartan EP Impurity F VE0027961
- N-Nitroso Losartan EP Impurity I VE0027962
- N-Nitroso Losartan EP Impurity J VE0027963
- N-Nitroso Losartan EP Impurity K VE0027964
- N-Nitroso Losartan EP Impurity L VE0027968
- N-Nitroso Losartan EP Impurity M VE0027970
- N-Nitrosodiethylamine (NDEA) VL3850024
CAS 55-18-5 - N-Nitrosodimethylamine (NDMA) VL3850010
CAS 62-75-9 - Nitroso BCFI Impurity VE007670
Additional information on N-Nitroso Losartan EP Impurity E
| Parent drug | Losartan |
|---|---|
| Product type | Impurity standards, Nitroso impurities |
| IUPAC name | 5-(4'-methyl-[1,1'-biphenyl]-2-yl)-1-nitroso-1H-tetrazole |
| SMILES | CC(C=C1)=CC=C1C(C=CC=C2)=C2C3=NN=NN3N=O |
| InChI | InChI=1S/C14H11N5O/c1-10-6-8-11(9-7-10)12-4-2-3-5-13(12)14-15-16-17-19(14)18-20/h2-9H,1H3 |
| InChIKey | YRXPBCLSBZSJDE-UHFFFAOYSA-N |
| CHNS Ratio (%) (calculated) | C 63.39 · H 4.18 · N 26.40 · S 0.00 |
| Description | N-Nitroso Losartan EP Impurity E is a nitrosamine-class impurity identified in losartan drug substance batches, characterized by high genotoxic concern and low-level occurrence. Analytical identification typically relies on sensitive LC-MS/MS and GC-MS methods with validated extraction and sample preparation protocols to achieve sub-ppb detection limits. Its formation is associated with nitrosation of amine precursors under acidic or nitrosating conditions, prompting control strategies such as precursor removal, process parameter optimization, and in-process monitoring. Regulatory assessment follows ICH M7 guidance for mutagenic impurities, with establishment of specification limits, stability profiling, and routine release testing to ensure product safety and compliance. |