Nintedanib Nitroso Impurity-1Veeprho vpb236c4c72eOONNOONHNONN
  • 100% accuracy of data
  • 24/7 scientific support
  • 0% tolerance in quality of product

Mutagenicity assessment (ICH M7)

ICH M7 class 1–3

Potentially mutagenic impurity (ICH M7 Class 1–3).

N-nitroso compound: ICH M7 cohort of concern.
Request mutagenicity assessment

Stock Locations

  • New Jersey, USA
  • Czech Republic, EU

* Stock subject to availability.

Documentation

Includes: HPLC, MASS/LC-MS, 1H NMR, FT-IR, Potency, Structure Elucidation Report (SER), and additional analytical data depending on the product.

Nintedanib Nitroso Impurity-1

● Under Development

Catalogue No.:VE009400
CAS No.:N/A
Mol. Formula:C31H32N6O5
Mol. Weight:568.62 g/mol
Request a quote

For laboratory use only: analytical, development and regulatory purposes. Supplied in mg quantities. Not for human or veterinary use.

Request a quote for a set

Additional information on Nintedanib Nitroso Impurity-1

Parent drugNintedanib
Product typeImpurity standards, Nitroso impurities
IUPAC namemethyl (Z)-3-(((4-(N-methyl-2-(4-methylpiperazin-1-yl)acetamido)phenyl)amino)(phenyl)methylene)-1-nitroso-2-oxoindoline-6-carboxylate
SMILESCOC(=O)c1ccc2c(c1)N(N=O)C(=O)/C2=C(\Nc1ccc(N(C)C(=O)CN2CCN(C)CC2)cc1)c1ccccc1
InChIKeyWVGHBTXAUKVRDE-ZIADKAODSA-N
CHNS Ratio (%) (calculated)C 65.48 · H 5.67 · N 14.78 · S 0.00
ReferencesRivera-Ortega, Pilar, et al. ?Nintedanib in the Management of Idiopathic Pulmonary Fibrosis: Clinical Trial Evidence and Real-World Experience.? Therapeutic Advances in Respiratory Disease, vol. 12, Jan. 2018, p. 175346661880061, https://doi.org/10.1177/1753466618800618. ?
Description

N-Nitroso Nintedanib is an N-nitroso derivative of the secondary amine present in Nintedanib | which is a highly characterized reference material that meets stringent regulatory standards set for nitrosamine compounds | including those set by USP | EMA | JP | and BP. This nitroso standard is essential for a variety of applications | such as analytical method development | method validation (AMV) | and Quality Control (QC) | particularly in the context of Nintedanib production. It is suitable for use in both Abbreviated New Drug Applications (ANDA) and New Drug Applications (NDA). This nitrosamine standard helps establish detection limits | quantify impurity levels | and ensure trace nitroso impurities in pharmaceutical products remain within FDA and EMA safety limits.⁠‌​‌‌​​‌​​​‌‌​‌‌​‌‌​​​‌​​‌‌​​​‌‌‌​​‌​‌‌‌​⁠